3WI.COM

HOTLINE: +86-021-64601150
Japan Products

D/8 UV Whiteness index 360 740 nm SCI/ SCE CM

2017-09-04      Click:371
Aperture: 8mm/4mm Structure: 8/d
Color Space: CI E L AB,XYZ,LCh,CI E RGB,CI E LUV Observer: CI E 10°
Repeatability: ΔE* Ab 0. 03 PC Software: CQCS3 Software
 

 

CM-3600A Spectrophotometer

Horizontal aligned Spectrophotometer for reflectance & transmission


The CM-3600A Spectrophotometer is a high-reliability and high-precision instrument that can deal with a wide range of applications. Its ability to easily measure subjects renders it one of the most prevalent bench top spectrophotometers. The CM-3600A uses a horizontal side-port format. It is a compact and reliable workhorse that can measure the reflectance of a wide variety of subjects, as well as the transmittance of translucent or transparent solids and liquids without taking up much space.

 

· Numerical Gloss Control Provides Simultaneous SCI/SCE Measurements - The CM-3600A utilizes 日本 s patented Numerical Gloss Control system, eliminating the need for a mechanical gloss trap. By firing two xenon lamps in quick succession, the system can provide virtually simultaneous SCI (specular component included)/SCE (specular component excluded) measurements and also enable the calculation of 8 degree gloss.

· Numerical UV Control for Accurate Measurements of Fluorescent Materials - Accurate measurement of materials such as paper or cloth treated with fluorescent whitening agents (FWA) requires precise control of the UV component and its effects. The patented Numerical UV Control method used by the CM-3600A can provide such control by using proprietary calculations to combine the results from flashes of two xenon lamps: one with full UV energy, the other with UV energy removed by a UV-cutoff filter (either 400 nm or 420 nm). This method eliminates the need for mechanical filter positioning and repeated filter position adjustment, and enables UV adjustment by Whiteness Index, Tint, Brightness, or UV profile.

· Reflectance and Transmittance in One Instrument - The CM-3600A can measure both the reflectance of opaque objects and the transmittance of transparent or translucent solid materials such as plastics. (With accessories, the CM-3600A can even measure the transmittance of liquids.) For reflectance measurements, the CM-3600A employ di:8 degree, de:8 degree (diffuse illumination, 8 degree viewing) geometry which conforms to ISO, CIE, ASTM, DIN, and JIS standards. For transmittance measurements, the CM-3600A employ d:0 degree (diffuse illumination, 0 degree viewing) geometry which conforms to ISO, CIE, ASTM, and DIN standards.

· Bright, Clear Sample Viewer for Accurate Sample Positioning - Opening the sample viewer provides a clear, illuminated view of the sample at the measurement port. On the CM-3600A, this view is reflected in a mirror on the sample viewer cover so that you can view it easily even while seated.

· Three Measurement Areas For Diverse Needs - Masks for the CM-3600A s three measurement areas (SAV: Diameter 4 mm, MAV: Diameter 8 mm, and LAV: Diameter 25.4 mm) are included as standard accessories, so you can select the one that fits your measurement requirements.

· Full Data Compatibility with CM-3600d and CM-3610d - Since the CM-3600A utilize the same design and innovative technology as their predecessors CM-3600d and full data compatibility is assured.

· USB Data Communication - Data communication between the CM-3600A is performed via USB to offer higher speed.

· RoHS Compliance - The CM-3600A is in full conformance with the RoHS (Restrictions on Hazardous Substances Directive) to ensure that they are environmentally friendly.

· Small footprint - Despite having a 152-mm integrating sphere and being packed full of advanced functionality, the CM-3600A is extremely compact, with a footprint about the same as a sheet of B4 paper or an average laptop computer. It can fit easily in a limited space while still providing the versatility and high accuracy of larger models. Measures both reflectance and transmittance, including transmittance of liquids

· Reflectance - The CM-3600A can measure reflectance using di:8 deg, de:8 degree (diffuse illumination, 8 degree degree viewing) geometry which conforms to ISO, CIE, ASTM, DIN, and JIS standards

· Transmittance - The CM-3600a can measure the transmittance of both solid and liquid materials using d:0 deg (diffuse illumination, 0 degree viewing) geometry which conforms to ISO, CIE, ASTM, and DIN standards

· Improved sample holder - The sample holder opens approximately 90 degree for easy positioning of samples. It also has a new soft-close mechanism that prevents it from slamming shut and damaging samples or pinching fingers.

· Bright, clear sample viewer can be used even while seated - The sample viewer lets the sample be seen clearly at the measuring port for accurate positioning. When the sample viewer cover is opened, a high-brightness LED illuminates the sample to provide a clear image, and the cover is equipped with a mirror so that the image can be seen even from a seated position.

 

 

 

 

Specifications:

Illumination/observation system Reflectance; di:8 degree, de:8 degree; (diffused illumination, 8 degree viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded); Conforms to CIE No.15, lSO7724/1, ASTM E-1164, DIN 5033 Teil7 and JIS Z8722 condition C standard.
Transmittance : di:0 degree, de:0 degree (diffused illumination, 0 degree viewing); Conforms to CIE No.15, ASTM E-1164 and DIN 5033 Teil7 standard.
Light-receiving element Silicon photodiode array (dual 40 elements)
Spectral separation device Diffraction grating
Wavelength range 360 to 740 nm
Wavelength pitch 10 nm
Half bandwitdh Approx. 10 nm
Reflectance range 0 to 200%; Resolution: 0.01%
Sphere size Diameter 152 mm
Light source Four pulsed xenon lamps
Minimum interval between measurements Normal SCI/ SCE measurement: 4 sec. UV-cut / UV-adjusted measurement: 5 sec. Transmittance measurement: 3 sec.
Measurement/illumination areas Reflectance: Changeable between LAV, MAV, and SAV
LAV: Diameter 25.4 mm / Diameter 30 mm
MAV: Diameter 8 mm / Diameter 11 mm
SAV: Diameter 4 mm / Diameter 7 mm
Transmittance: Approx. O 24 mm

 

 

NR60CP COLOR METER

 

 

 

Features:

  1. 8mm and 4mm double aperture for switch, easy to measure concave sample in large plane

  2. More stable and accuracy, Delta E ab<0.03

  3. Many color spaces, many color indexes, extensive applicability

  4. Double locating: illuminating locating and cross locating

  5. Equipped with rechargeable high-capacity li-ion battery

  6. Built-in white plate parameters, and configuration of physical whiteboard, easy to operate;

  7. New integrating sphere optical path design, more stable to measure;

  8. Double apertures measurement data can pass SCM metrological certification;

Specifications:

Model

NR60CP

Illuminating/Viewing Geometry

8° / d; CI E No. 15,GB/ T 3978

Light Source

LED sources

Sensor

Silicon photodiode array

Measuring Aperture

Φ8mm large area end-face; Φ4mm small area concave-convex end-face

Color Space

CI E L AB,XYZ,LCh,CI E RGB,CI E LUV

Other Chromaticity Data

WI ( E313,CI E, AATCC,Hunt er ),YI ( D1925, 313),Color Fastness, Staining Fastness, J PC79,BFD( 1. 5: 1),FMCI I

Observer

CI E 10°

Illuminant

D65,A,C,D50,F2,F6,F7,F8,F10,F11,F12

Display Data

Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset,

Measurement Time

0. 4s

Repeatability

ΔE* ab 0. 03(Average of 30 measurement of standard white plate within 5s)

Errors between each instrument

within Delta E*ab 0.2

Dimension

(L*W*H)205*67*80mm

Weight

500g

Battery

rechargeable lithium-ion battery 3. 7V @ 3200mAh

Lamp Life

5 years, more than 1.6 million measurements

Display Screen

TFT 2.8 inch(16: 9)

Interface

USB/RS-232

Data Memory

100 Standards, 20000 Samples

Operating Temperature

0~40℃(32~104°F)

Storage temperature

-20~50℃(-4~122°F)

Optional Accessory

miniature thermal printer, powder test box

Warranty:

All our products have one year warranty. If it has something wrong during warranty, you can send it back to us. The buyer pays for the returning shipping cost and we will pay for the sending shipping cost.

NR60CP colorimeter


PRE : Multi Gloss 268 / MG268 Ultra-compact portabl
NEXT : Spectrodensitometer FD-5 enables colour evalu